Bien Air CA 1/1 L + PM 1/1 Standard Handpiece Combo

Customize Bien Air CA 1/1 L + PM 1/1 Standard Handpiece Combo
Bien Air CA 1/1 L Standard Handpiece   + ₹0.00
Bien Air PM 1/1 Standard Handpiece   + ₹0.00

* Required Fields

Your Customization
Bien Air CA 1/1 L + PM 1/1 Standard Handpiece Combo
Bien Air CA 1/1 L + PM 1/1 Standard Handpiece Combo

In stock

₹73,800.00

Summary

    In stock

    SKU
    bien-air42342gjdfkgfd

    From ₹73,800.00

    To ₹73,800.00

    CA 1/1 L + PM 1/1 Standard Handpiece
    Bien-Air's classic CA 1:1 electric handpiece are forever evolving, their dominating productivity and remarkable durability make them the most popular models in the lineup. The series fully redesigned bur-locking and rotation drive mechanism ensures micron-precise concentricity and stability, while a 60 to 2,00,000 rpm speed range lets you complete the most intricate restorative work with incredible accuracy. CA 1:1 epitomize the reliability and quality Bien-Air has built its reputation on.
     
    PREPARATION
    A.

    REMOVING THE INSTRUMENT

    • Remove the rotary instrument from the chuck mechanism
    • Disconnect the contra-angle from the motor
    B.

    PRE-DISINFECTION

    • External disinfection

    Do not immerse the instrument in a disinfectant bath.

    CLEANING
    A.

    CLEAN UNDER RUNNING WATER AT <38°C

    B.

    REMOVING DIRT/DEPOSITS

    • Carefully remove all traces of dirt or deposits from the nozzles using the Bien-Air cleaning wire
    • Dry the nozzles with compressed air then dry the rest of the instrument with a cloth

    Do not immerse in an ultrasonic cleaner

    C.

    INTERNAL AND EXTERNAL CLEANING WITH SPRAYNET

    • Shake the Spraynet before use
    • Use the Spraynet attachment 1
    • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second
    • Clean the exterior of the contra-angle with a cloth soaked in Spraynet
    DISINFECTION
    A.

    DISINFECTION USING SURFACE DISINFECTANT (follow the manufacturer's instructions for use)

    Do not immerse the instrument in a disinfectant bath

    OR
    B.

    THERMAL DISINFECTION (follow the manufacturer's instructions for use)

    LUBRICATION
    A.

    LUBRICATION WITH LUBRIFLUID

    • Shake the Lubrifluid before usen
    • Use the Lubrifluid attachment 1
    • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second
    • Then, run an operating test for 30 seconds at low speed to remove any surplus lubricant
    • Store immediately: store the instruments with the tip pointing downwards so that any oil residues can flow out
    STERILISATION
    A.

    PLACE THE CONTRA-ANGLE IN A STERILISATION BAG

    B.

    STERILISE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS

    • Instruments bearing the "135°C" can be sterilised in an autoclave

    Only sterilise instruments which have been cleaned and lubricated